IR Optical Dome for Industrial Furnace Thermal Monitoring Case Study

IR Optical Dome for Industrial Furnace Thermal Monitoring Case Study

Summary

European furnace OEM needed a custom ZnS IR dome to enable continuous 8-14μm LWIR thermal imaging through high-temperature furnace wall. Previous CaF2 window cracked after 3 months. Our multispectral CVD ZnS dome with broadband IR AR coating delivered >72% transmission and 12+ months trouble-free operation.

Case Study

IR Optical Dome for Industrial Furnace Thermal Monitoring

Custom ZnS multispectral IR dome enables continuous 8–14μm thermal imaging through high-temperature furnace wall

Customer Background

A European industrial furnace OEM needed a custom IR window dome to mount on their continuous annealing furnace. The dome must withstand external temperatures up to 200°C while allowing a LWIR thermal camera (8–14μm) to monitor the internal furnace process without opening the door.

Previous solution used a generic CaF2 window that cracked after 3 months due to thermal cycling and furnace atmosphere condensation.

Technical Challenges

High Temperature Cycling

Furnace cycles from 25°C to 200°C daily — material must resist thermal shock and avoid delamination.

LWIR Transmission 8–14μm

Thermal camera operates in 8–14μm band; dome material must transmit >70% across full range.

Furnace Atmosphere

Steam and mild chemical condensation inside furnace — coating must be durable and cleanable.

Hemispherical Shape

Customer required hemispherical dome (not flat window) to match existing camera port flange geometry.

Material Selection Process

We evaluated three candidate IR materials against the customer's requirements:

Material 8–14μm Transmission Max Temp Cost Level Selected?
Multispectral ZnS >70% (full 8–14μm) ~250°C continuous Medium ✓ SELECTED
CVD ZnSe >70% (best in 10.6μm peak) ~250°C continuous High ✗ Overkill (laser grade not needed)
Germanium Good, but absorbs above 100°C ~80°C limit High ✗ Fails temp requirement

We recommended multispectral CVD ZnS as the optimal balance of LWIR transmission, temperature resistance and cost. Learn more about material options in our ZnS optical glass material guide.

Our Solution

  • Material: CVD multispectral ZnS, polished to optical grade
  • Geometry: Hemispherical dome, OD 89mm, wall thickness 4mm
  • Coating: Broadband IR AR coating (7–14μm), designed for high-temperature operation
  • Mounting: Flange ground to customer's furnace port drawing, O-ring groove for hermetic seal
  • Tolerance: Surface quality 60/40, transmission >70% across 8–14μm band

Test Results & Field Performance

>72%
Average Transmission (8–14μm)
>12 months
Continuous Furnace Operation
0 failures
Thermal Cycle Tests Passed

Customer reported stable thermal imaging readings and no dome cracking or coating delamination after 12+ months of continuous furnace operation. They have since placed repeat orders for 12 additional furnace units.

Related Resources