Custom NIR Bandpass Filter | 400-1100nm AR ITO - Felix Glass
Custom NIR Bandpass Filter | 400-1100nm AR ITO - Felix Glass
Custom NIR Bandpass Filter | 400-1100nm AR ITO - Felix Glass
Custom NIR Bandpass Filter | 400-1100nm AR ITO - Felix Glass
Custom NIR Bandpass Filter | 400-1100nm AR ITO - Felix Glass
Custom NIR Bandpass Filter | 400-1100nm AR ITO - Felix Glass
Price
US $8.6-14.8
Model
FG-LWIR-4001100-FS
MOQ
1 piece

Item specifics

Substrate
: Fused silica quartz glass
FWHM
(Customizable)
Peak Transmission
≥90% peak transmittance,
Core Spec
: 400–1100nm passband,
Shape
Custom round disc, square sheet
Coating
AR+ITO dual coating
Application
Industrial optical inspection, spectral measurement, near-infrared detection

Review

Description

Custom NIR Bandpass Filter

Send your drawing or sample requirement for a fast quotation. MOQ, lead time and coating options are confirmed within one business day.

Request a Quote

400-1100nm NIR
Fused Silica
AR + ITO Coating
≥90% Peak Transmission
EMI Shielding
Custom Size & Shape

400–1100nm Bandpass Filter
with AR & ITO Coating on Fused Silica

Custom near-infrared broadband bandpass filter on high-purity fused silica, combining dual anti-reflection coating with a conductive ITO layer. Delivers ≥90% peak transmission across 400–1100 nm while providing electromagnetic shielding for optical windows in industrial inspection, machine vision, spectral analysis and medical IR imaging.

  • Broad Passband 400 nm – 1100 nm (Visible to NIR)
  • Peak Transmission ≥ 90% Within Passband
  • High-Purity Fused Silica Quartz Substrate
  • Dual AR Coating + Conductive ITO Layer
  • EMI / RFI Shielding for Optical Windows
  • Custom Round, Square & Special Shapes
  • Custom Out-of-Band Blocking per Drawing
Engineering Commitment: Send your spectral range, peak transmission target, out-of-band blocking requirement, dimension and AOI. Our optical engineers will review your system integration and recommend a matched AR+ITO filter stack — with sample spectral curves for your validation.
400-1100nm NIR bandpass filter with AR and ITO coating on fused silica

Why Do Optical System Engineers Switch to Our AR+ITO Filters?

Pain Points With Generic NIR Filters Felix Glass Solution
Generic AR-only filter has no conductive layer, EMI noise leaks into the detector Dual AR + ITO stack: AR boosts transmission, ITO layer provides surface conductivity and EMI/RFI shielding for the optical window.
Peak transmission only 80–85%, loses signal margin in low-light NIR inspection Precision multi-layer AR coating engineered for ≥90% peak across 400–1100 nm, with spectral curve tested and provided per lot.
BK7 substrate absorbs at NIR edge, drifts under wide-temperature operation High-purity fused silica substrate with low intrinsic absorption and excellent thermal stability for industrial temperature cycling.
Standard off-the-shelf size cannot fit your instrument housing or optical path Custom round disc, square sheet, special outline, thickness and edge blackening to your mechanical drawing.
Out-of-band blocking not specified, stray light degrades measurement accuracy Custom blocking levels and edge blackening per your spectral requirement, not a one-size-fits-all passband.
Supplier cannot support small prototype batch for instrument R&D Prototype sampling, small trial batches and mass production all supported, with spectral data for each sample.
No spectral test report delivered, hard to validate incoming quality Every filter passes UV-Vis-NIR spectrophotometer test; transmission curve and surface inspection report ship with the lot.

Why Optical Instrument Manufacturers Work With Felix Glass

19+ Years

Optical Glass & Coating Experience

400-1100 nm

Broad Visible-to-NIR Passband

≥90%

Peak Transmission in Passband

Fused Silica

Low Absorption, Thermally Stable

Custom Blocking

Out-of-Band Suppression per Drawing

Spectral Test

Transmission Curve per Lot

*Actual peak transmission, blocking and AOI depend on coating design and substrate.

One supplier from fused silica cutting and polishing to precision AR+ITO coating, edge blackening and spectrophotometer testing. We control the full optical stack in-house, so your NIR filter arrives dimensionally accurate, spectrally validated and ready to integrate.

AR+ITO Bandpass Filters Engineered for Your Optical System

NIR Industrial Inspection & Machine Vision

Broad 400–1100 nm passband for near-infrared defect inspection, sorting, surface measurement and automated machine vision systems.

  • High transmission across visible + NIR
  • Fused silica for stable thermal operation
  • Edge blackening to suppress stray light
  • Custom format to fit camera housing

Recommended Solution: Fused Silica + AR Coating + Edge Blackening

Discuss Your Inspection System →

Spectral Analysis & Measurement Instruments

Custom bandpass for spectrophotometers, color measurement, optical test benches and laboratory analytical instruments requiring defined passbands.

  • Custom center wavelength and bandwidth
  • Specified out-of-band blocking levels
  • Spectral curve delivered per lot
  • 0° standard, custom AOI supported

Recommended Solution: Fused Silica + Precision AR Stack + Custom Blocking

Discuss Your Spectral Requirement →

EMI Shielded Conductive Optical Window

When your optical window sits in an electrically noisy environment, the ITO layer provides surface conductivity for EMI/RFI shielding without blocking the optical passband.

  • ITO layer adds conductive coating over AR
  • Blocks electromagnetic interference
  • Maintains ≥90% optical transmission
  • Ideal for sealed enclosures and detector windows

Recommended Solution: Fused Silica + AR + ITO Conductive Stack

Discuss Your Shielding Requirement →

Medical IR Imaging & Detection

Custom bandpass filters for medical infrared imaging, thermography, clinical detection and life-science optical instruments.

  • Biocompatible fused silica substrate
  • Precision passband for medical detector
  • Clean packaging for medical assembly
  • Optional anti-bacterial surface treatment

Recommended Solution: Medical-grade Fused Silica + AR + ITO Stack

Discuss Your Medical Optics Project →

Core Optical Specifications

ItemParameter
Passband Range400 nm – 1100 nm broadband transmission (Visible to NIR)
Peak Transmission≥ 90% within 400–1100 nm spectrum
SubstrateHigh-purity fused silica quartz glass
Functional CoatingDual AR anti-reflection coating + conductive ITO coating
ShapeCustom round disc, square sheet, arbitrary tailor-made dimensions
AOI (Angle of Incidence)0° standard, custom incident angle supported
Out-of-Band BlockingCustom suppression level available per drawing
Edge TreatmentEdge blackening, precision grinding, chamfering optional
ThicknessCustom per requirement (standard 1 mm – 6 mm range)
TestingUV-Vis-NIR spectrophotometer spectral curve per lot

*Subject to coating design, substrate and customer-specific spectral requirements.

Typical AR+ITO Filter Project Examples

Machine Vision NIR Inspection Window

Customer Requirement

Automated optical inspection OEM needed a sealed NIR window for a production-line camera, 400–1100 nm passband, EMI shielding inside an enclosed metal housing, custom round format with edge blackening.

Our Solution

Fused silica substrate precision-cut to round format, dual AR coating for high transmission, ITO conductive layer for EMI shielding, edge blackening to suppress stray light, spectrophotometer curve per sample.

Typical Project Outcome

Samples approved for camera integration, EMI performance met spec, moved to monthly batch supply for inspection line deployment.

Spectrometer Custom Bandpass Filter

Customer Requirement

Scientific instrument manufacturer needed custom bandpass filters with specified out-of-band blocking for a laboratory spectrophotometer, small prototype batch with spectral curves for calibration.

Our Solution

Fused silica substrate, precision coating stack designed for target passband and blocking, custom edge grinding, each filter tested on UV-Vis-NIR spectrophotometer with delivery curve.

Typical Project Outcome

Prototype filters delivered with spectral data, validated against instrument calibration, approved for follow-up production batch.

From Spectral Drawing to Tested AR+ITO Filter

01 Requirement Review

Verify passband, peak transmission, blocking level, AOI, dimension and substrate requirement.

02 Substrate Cutting

Fused silica cutting to round, square or custom outline per mechanical drawing.

03 Polishing & Grinding

Precision surface polishing and edge grinding to optical flatness specification.

04 AR Coating Design

Multi-layer AR coating engineered for ≥90% peak across 400–1100 nm.

05 ITO Conductive Layer

Sputtered ITO over AR stack for surface conductivity and EMI shielding.

06 Edge Blackening (Optional)

Light-absorbing edge treatment to suppress stray light in imaging systems.

07 Spectral Testing

UV-Vis-NIR spectrophotometer measurement of transmission curve per lot.

08 QC & Clean Packaging

Surface inspection, dimensional check and clean packaging ready for integration.

Why Start With a Filter Prototype?

01 Validate Spectral Performance

Test the actual transmission curve and blocking level in your optical setup before committing to volume.

02 Verify Mechanical Fit

Confirm dimension, edge treatment and mounting format fit your instrument housing and optical path.

03 Reduce Integration Risk

Validate AR+ITO stack performance in your real detector and EMI environment before production order.

Not Sure Which Filter Configuration You Need?

Your ApplicationRecommended Solution
Machine vision, NIR industrial inspectionFused silica + AR + edge blackening, custom round/square format
EMI-shielded optical window in sealed enclosureFused silica + AR + ITO conductive stack
Spectrophotometer, spectral measurement instrumentCustom passband + specified out-of-band blocking, spectral curve per lot
Medical IR imaging, thermographyMedical-grade fused silica + AR+ITO, clean packaging
High-power laser or laser protection windowConsider our longpass fused silica filter with AR+ITO coating
Wide-temperature industrial environmentFused silica over BK7 for thermal stability and low absorption
Small R&D batch or instrument validationPrototype sampling with spectral data for your calibration

Still unsure about coating stack or blocking level? Ask Our Optical Engineers for Free Guidance

Frequently Asked Questions

Q: What spectral range does this NIR bandpass filter cover?
A: It offers continuous broadband transmission from 400 nm to 1100 nm, covering visible light through the near-infrared long-wave spectrum, suitable for general industrial optical detection, machine vision and spectral analysis.
Q: Why fused silica instead of BK7 for this filter?
A: High-purity fused silica provides lower intrinsic absorption, better thermal stability and wider spectral range than ordinary BK7 glass. This is important for NIR operation and wide-temperature industrial environments.
Q: What do the AR and ITO coatings each do?
A: The AR anti-reflection coating boosts peak transmission to ≥90% across the passband. The conductive ITO layer adds surface conductivity for EMI/RFI shielding, turning the optical window into a shielded conductive component.
Q: Can I customize the size and shape?
A: Yes. We support custom round discs, square sheets, special outlines, adjusted thickness, edge blackening and specific out-of-band blocking parameters per your technical drawing.
Q: Do you provide sample and mass production?
A: We offer prototype sampling, small trial batches and large-scale manufacturing. Every filter passes complete spectral and surface inspection before shipment, with transmission curve data available.
Q: What angle of incidence is supported?
A: Standard is 0° normal incidence. Custom AOI requirements can be accommodated depending on coating design; please specify your working angle during inquiry.
Q: Can you specify out-of-band blocking levels?
A: Yes. Out-of-band suppression is custom-engineered based on your spectral requirement. Send us the blocked wavelength regions and required optical density, and we will design the coating stack.
Q: Do you ship with spectral test data?
A: Yes. Each lot is measured on a UV-Vis-NIR spectrophotometer; the transmission curve and surface inspection report ship with the filters for your incoming quality validation.
Q: What is the typical lead time for prototypes?
A: Standard prototype samples are typically 7-10 working days depending on coating complexity; custom blocking designs may take longer. Bulk lead time is confirmed per PO.
Q: What information do you need for a quote?
A: Passband requirements, peak transmission target, out-of-band blocking, dimension and shape, AOI, substrate preference (fused silica vs other), quantity, and whether you need EMI/ITO conductive layer. Incomplete specs are acceptable for preliminary evaluation.

Request Custom 400-1100nm AR+ITO Bandpass Filter

Tell us your spectral requirement and mechanical drawing. Our optical engineers will design a matched coating stack and quote fast.

Before You Send Your Inquiry, Prepare These Inputs

  • Passband requirement: 400-1100 nm standard, or custom center wavelength / bandwidth
  • Peak transmission target: e.g. ≥90% in passband
  • Out-of-band blocking: blocked wavelength regions and required optical density
  • Substrate: fused silica (recommended for NIR) or other material
  • Dimension & shape: round diameter, square size, thickness, special outline
  • AOI: 0° standard, or custom incident angle
  • ITO / EMI requirement: conductive ITO layer for shielding, or AR-only

Free optical engineering review · spectral curve per lot · 19+ years optical coating manufacturing

Explore More Optical & ITO Coating Resources

Have a NIR Filter or Optical Window Project? Let's Review It.

Send your spectral requirement or mechanical drawing. You don't need to finalize every coating parameter. Our optical engineers will recommend the right AR+ITO stack for your system.

Free optical engineering review · spectral curve per lot · OEM/ODM manufacturing