Medical Grade ITO Conductive Glass | Hospital Equipment - Felix Glass
Medical Grade ITO Conductive Glass | Hospital Equipment - Felix Glass
Medical Grade ITO Conductive Glass | Hospital Equipment - Felix Glass
Medical Grade ITO Conductive Glass | Hospital Equipment - Felix Glass
Medical Grade ITO Conductive Glass | Hospital Equipment - Felix Glass
Medical Grade ITO Conductive Glass | Hospital Equipment - Felix Glass
Price
US $2.8-6.03
Model
MDG-0545
MOQ
5 piece

Item specifics

Base Substrate
Medical aluminosilicate glass / UV fused silica (quartz)
ITO Coating Composition
In₂O₃:SnO₂, film thickness 100–200 nm
Sheet Resistance
5 Ω/sq, 10 Ω/sq, 15 Ω/sq, 20 Ω/sq medical grade uniform coating
Visible Transmittance
≥85% @ 550 nm
Standard Sizes
30×40mm, 100×150mm, 21.5-inch touch panel blank, custom dimensions
Glass Thickness
0.7mm, 1.1mm, 1.8mm, 3.0mm
Biocompatibility Standard
ISO 10993 Cytotoxicity & Skin Irritation Passed
Disinfection Resistance
Resistant to alcohol, medical disinfectant, hydrogen peroxide cleaning
Optional Functional Coating
Anti-glare (AG), anti-fingerprint (AF), anti-bacterial coating
Surface Roughness
≤3 nm RMS for clinical optical detection
Custom Processing
CNC cutting, drilling, edge chamfering, selective ITO etching & patterning
Max Continuous Working Temp
≤220°C

Review

Description

Medical Grade ITO Conductive Glass

Send your drawing or sample requirement for a fast quotation. MOQ, lead time and coating options are confirmed within one business day.

Request a Quote

Medical Grade
ISO 10993
Hospital Equipment
Touch Panel
Biosensor Substrate
OEM / ODM

Medical Grade ITO Conductive Glass
for Hospital Equipment & Medical Devices

ISO 10993 biocompatible ITO conductive glass for patient monitors, ultrasound control panels, CT displays, wearable medical sensors, IVD instruments and biosensor chips. Magnetron-sputtered ITO on aluminosilicate or fused silica, engineered to survive repeated hospital disinfection cycles.

  • ISO 10993 Cytotoxicity & Skin Irritation Passed
  • Sheet Resistance 5 / 10 / 15 / 20 Ω/sq (Uniform Coating)
  • Visible Transmittance ≥ 85% @ 550 nm
  • Aluminosilicate or Fused Silica Substrate
  • Resistant to Alcohol, Isopropanol & Medical Disinfectant
  • Optional AG / AF / Silver-ion Anti-Bacterial Coating
  • Custom Etching for Biosensor Electrode Circuits
Engineering Commitment: Send your device type, target sheet resistance, finished size and required functional coating. Our optical engineers will review your medical device design and recommend a matched ITO substrate configuration — with biocompatibility documentation for your regulatory file.
Medical grade ITO conductive glass for hospital equipment

Why Do Medical Device Engineers Switch to Felix Glass Medical ITO?

Pain Points With Generic ITO Glass in Medical Devices Felix Glass Solution
ITO film peels or discolors after weeks of alcohol / disinfectant wiping on ward touch panels Dense sputtered ITO coating passes repeated ethanol, isopropanol and medical disinfectant exposure without resistance drift or delamination.
No biocompatibility documentation, blocks FDA / CE / NMPA device registration Every medical-grade lot ships with ISO 10993 cytotoxicity and skin irritation test reports, ready for your regulatory technical file.
Sheet resistance varies across the panel, causing uneven touch response on patient monitors In-house magnetron sputtering with in-line four-point-probe mapping ensures uniform resistance across the whole touch substrate.
Standard off-the-shelf sizes cannot fit custom bezel, cutout or sensor window CNC cutting, drilling, notch and edge grinding to your medical enclosure drawing, not a generic microscope slide.
UV diagnostic instruments blocked by borosilicate cutoff below 320 nm Fused silica quartz ITO option for UV-Vis-NIR 185–3500 nm, with ultra-low autofluorescence for bio-detection.
Biosensor chip needs custom electrode pattern, supplier cannot etch Selective ITO etching and patterning in-house, fabricating transparent electrode circuits for microfluidic diagnostic chips.
Shared ward touch panels grow biofilm, hospital hygiene complaints Optional silver-ion anti-bacterial surface coating suppresses bacteria colonization on multi-use medical touch surfaces.

Why Medical Device Manufacturers Work With Felix Glass

19+ Years

Optical Glass Manufacturing Experience

ISO 10993

Biocompatibility Test Reports Provided

10-15 Ω/sq

Standard Medical Touch Panel Grade

≥85%

Visible Transmittance @ 550 nm

100% Inspection

Resistance, Transmittance & Coating Uniformity

Global Ship

Medical Device Factories Worldwide

*Biocompatibility reports and actual resistance grades depend on substrate, coating and lot.

One supplier from substrate cutting to ITO sputtering, etching and functional coating. We control aluminosilicate / fused silica processing, medical-grade ITO deposition, four-point-probe testing and clean packaging — so your hospital equipment and medical device products ship with consistent, regulatory-ready transparent conductive glass.

ITO Glass Engineered for Your Medical Device

Hospital Touch Screens & Patient Monitors

Capacitive touch substrate for patient monitors, ultrasound machines, anesthesia workstations, CT/MR control panels and ward medical displays.

  • 10-15 Ω/sq standard touch grade
  • Aluminosilicate, impact and scratch resistant
  • Disinfection-stable ITO for daily ward cleaning
  • Optional anti-bacterial silver-ion coating

Recommended Solution: Aluminosilicate + 10-15 Ω/sq ITO + Optional AF / Anti-Bacterial

Discuss Your Touch Panel →

Biosensors & Microfluidic Diagnostic Chips

Custom-etched transparent electrode substrates for IVD lab-on-chip, biochemical analyzers, cell electrophysiology detectors and rapid diagnostic cartridges.

  • Selective ITO etching for electrode circuits
  • Quartz option for UV bio-detection
  • Low autofluorescence for optical readout
  • Drilled access holes and alignment notches

Recommended Solution: Quartz or Borosilicate + Patterned ITO + Custom Etching

Discuss Your Biosensor Chip →

Wearable Medical & Optical Detection Windows

Thin, lightweight conductive glass windows for continuous glucose monitoring patches, PPG heart-rate sensors, ophthalmic ERG/EOG detection and endoscope display protection.

  • Thin 0.7 mm and 1.1 mm options
  • Optical-grade polished surface
  • Uniform conductivity for stable signal capture
  • Custom outline for wearable device housing

Recommended Solution: Thin Aluminosilicate + Optical Polish + Custom Outline

Discuss Your Wearable Sensor →

Lab Research & Cell Culture Substrates

ITO slides and custom substrates for cell culture transparent electrodes, medical biological research, electrophysiology experiments and academic collaboration.

  • 20×20, 25×75 mm standard slide format
  • Low roughness for uniform cell growth
  • Small prototype batches for R&D labs
  • See our dedicated lab ITO electrode page

Recommended Solution: Send us your research setup, we recommend substrate and resistance grade

View Lab ITO Electrode Slides →

Core Technical Specifications

ItemParameter
Base SubstrateMedical aluminosilicate glass / UV fused silica (quartz)
ITO CoatingIn₂O₃:SnO₂, film thickness 100-200 nm, magnetron sputtered
Sheet Resistance5 / 10 / 15 / 20 Ω/sq, medical-grade uniform coating
Visible Transmittance≥ 85% @ 550 nm
Standard Sizes30×40 mm, 100×150 mm, 21.5-inch touch panel blank, custom dimensions
Glass Thickness0.7 mm, 1.1 mm, 1.8 mm, 3.0 mm
BiocompatibilityISO 10993 cytotoxicity & skin irritation passed
Disinfection ResistanceResistant to alcohol, medical disinfectant, hydrogen peroxide cleaning
Optional CoatingAnti-glare (AG), anti-fingerprint (AF), anti-bacterial silver-ion
Surface Roughness≤ 3 nm RMS for clinical optical detection
Custom ProcessingCNC cutting, drilling, edge chamfering, selective ITO etching & patterning
Max Continuous Temp≤ 220°C

*Subject to substrate, resistance grade, functional coating and quantity.

Typical Medical ITO Project Examples

Patient Monitor Touch Panel Supply

Customer Requirement

Medical device OEM needing custom-cut ITO touch substrates for ward patient monitors, 10-15 Ω/sq, 21.5-inch blank, must survive daily alcohol disinfection, with ISO 10993 documentation for their CE registration.

Our Solution

Aluminosilicate substrate precision cutting, magnetron sputtered ITO (10-15 Ω/sq target), four-point-probe uniformity mapping, optional AF coating, ISO 10993 test reports and clean packaging per lot.

Typical Project Outcome

Sample panels approved, documentation accepted in their technical file, moved to monthly bulk supply for monitor production line.

Biosensor Chip Custom Etching

Customer Requirement

IVD startup needing patterned ITO on quartz substrate for a rapid diagnostic chip, custom electrode array per their mask layout, UV transmission for optical readout, small prototype batch for clinical validation.

Our Solution

Fused silica substrate cutting and polishing, ITO sputtering, selective etching per customer mask, drilled access holes, batch resistance and optical inspection, small-batch prototype delivery.

Typical Project Outcome

Prototype chips delivered on schedule, validated under customer's assay workflow, approved for follow-up pilot production order.

From Device Drawing to Regulatory-Ready ITO Glass

01 Drawing & Requirement Review

Verify size, thickness, target resistance, functional coating and regulatory documentation needs.

02 Material Selection

Aluminosilicate for touch panels; fused silica for UV diagnostic and bio-detection.

03 CNC Cutting & Shaping

Precision cutting, drilling, notching and edge grinding to your device enclosure drawing.

04 Polishing & Cleaning

Optical surface polishing for low roughness, strict cleanroom cleaning before coating.

05 Medical-Grade ITO Sputtering

Magnetron sputtering to target 5-20 Ω/sq, with post-coating annealing for disinfection stability.

06 Functional Coating (Optional)

AG, AF, silver-ion anti-bacterial or multi-layer EMI shielding composite.

07 Patterned Etching (If Needed)

Selective ITO etching for biosensor electrode circuits and custom touch routing.

08 QC, Docs & Packaging

100% resistance, transmittance and uniformity inspection, ISO 10993 documentation, clean packaging.

Why Start With a Medical-Grade Sample Batch?

01 Verify Device Fit

Confirm cutout, bezel, optical window and contact pad position fit your medical enclosure before bulk.

02 Validate Clinical Performance

Evaluate touch response, signal stability, disinfection resistance and optical clarity under real use.

03 Support Regulatory Filing

Sample lot ships with biocompatibility documentation you can directly attach to your technical file.

Not Sure Which Medical ITO Configuration You Need?

Your Device / ApplicationRecommended Solution
Patient monitor, ultrasound, anesthesia touch panelAluminosilicate + 10-15 Ω/sq ITO + optional AF / anti-bacterial
Ward shared touch panel, high hygiene requirementAluminosilicate + silver-ion anti-bacterial coating
IVD analyzer, biochemical instrument, UV detectionFused silica quartz ITO, UV-Vis-NIR transmission, low autofluorescence
Biosensor, microfluidic lab-on-chip, rapid cartridgePatterned / etched ITO with custom electrode circuit per mask
Wearable CGM patch, PPG sensor, thin windowThin aluminosilicate (0.7-1.1 mm) + optical polish + custom outline
Ophthalmic ERG/EOG, endoscope display protectionOptical-grade ITO glass with precision edge and AR/AG option
Cell culture, medical research substrateSee our dedicated lab ITO electrode slide page

Still unsure about substrate or coating? Ask Our Medical Glass Engineers for Free Guidance

Frequently Asked Questions

Q: What biocompatibility standard does this medical ITO glass comply with?
A: All medical-grade ITO products pass ISO 10993 cytotoxicity and skin irritation testing, with official test reports available for contact with biological samples and medical reagents. Documentation is ready to attach to your FDA / CE / NMPA technical file.
Q: Can the ITO film withstand daily hospital alcohol disinfection?
A: Yes. The dense sputtered ITO coating is stable under repeated ethanol, isopropanol and medical disinfectant wiping, without peeling, delamination or sheet-resistance drift over long-term clinical use.
Q: Aluminosilicate or fused silica quartz — how do I choose?
A: Aluminosilicate is the standard for hospital touch screens, patient monitors and wearable devices — impact resistant and cost effective. Fused silica quartz is required for UV diagnostic instruments, fluorescence bio-detection and any application needing full UV transmission below 320 nm.
Q: Is anti-bacterial coating available for shared ward touch panels?
A: Yes. We offer an optional silver-ion anti-bacterial surface coating that suppresses bacteria colonization on touch surfaces, ideal for multi-patient shared hospital equipment.
Q: Can you etch custom electrode patterns for medical biosensor chips?
A: Yes. We provide selective ITO etching to fabricate custom transparent electrode circuits for microfluidic diagnostic chips, rapid-test cartridges and cell electrophysiology substrates. Send us your mask layout and we will quote.
Q: Do you supply test samples for medical device certification?
A: Small-size prototype samples are available, together with biocompatibility inspection documents and lot test data to support your medical equipment registration and clinical validation.
Q: What sheet resistance is most widely used for medical touch screens?
A: 10-15 Ω/sq is the universal standard for hospital monitoring equipment touch panels. Lower 5 Ω/sq is used for high-current or large-format panels; higher grades are available for specific sensor applications.
Q: Do you support EMI shielding composite for diagnostic instruments?
A: Yes. We can supply multi-layer composite processing that reduces electromagnetic interference, helping precision diagnostic instruments avoid signal noise in hospital EM environments.
Q: What is the typical lead time for medical ITO samples?
A: Standard sample batches are typically 5-7 working days; custom etched or patterned medical chips depend on mask complexity. Bulk production lead time is confirmed per PO.
Q: What information do you need for a medical ITO quote?
A: Device type (touch panel / biosensor / wearable / IVD), substrate preference, finished size and thickness, target sheet resistance, required functional coating (AG / AF / anti-bacterial), and whether you need biocompatibility documentation. Incomplete specs are acceptable for preliminary evaluation.

Request Medical-Grade ITO Glass for Your Device

Tell us your device type and coating needs. Our engineers will recommend a matched ITO configuration — with regulatory documentation.

Before You Send Your Inquiry, Prepare These Inputs

  • Device type: patient monitor / ultrasound touch, biosensor chip, wearable sensor, IVD instrument, endoscope display, or other
  • Substrate: aluminosilicate (general clinical) / fused silica quartz (UV / fluorescence bio-detection)
  • Size & thickness: standard 30×40, 100×150, 21.5-inch blank, or custom dimension
  • Sheet resistance target: e.g. 5 / 10 / 15 / 20 Ω/sq
  • Functional coating: none, AG, AF, silver-ion anti-bacterial, or EMI shielding composite
  • Patterning: none, or custom electrode array drawing / mask for biosensor chips
  • Documentation needed: ISO 10993 test reports, lot resistance data, COA — or other regulatory file

Free engineering review · ISO 10993 documentation available · 19+ years optical glass manufacturing

Explore More Medical ITO Resources

Have a Hospital Device or Medical ITO Project? Let's Review It.

Send your device drawing, target resistance or coating requirements. You don't need to finalize every spec. Our engineers will recommend the right substrate and coating for your clinical application.

Free engineering review · ISO 10993 documentation available · OEM/ODM manufacturing